What you get: a zip file with two Word documents (.docx) and one Excel workbook (.xlsx, no macros). The form asks for your name and email address before the download starts; they are sent to Digital Adaption with the name of the file you asked for.
I built this as the landlord and HMO companion to the general fire risk assessment template. The general pack is for simple premises where nobody sleeps. This one is for buildings where people live, with shared kitchens, shared stairs, fire doors and alarms to look after.
Get the HMO fire risk assessment pack
One zip with three files: the HMO and landlord fire risk assessment (Word), the resident fire safety instructions and alarm test record (Word), and the fire action log (Excel) with overdue flags and automatic counts. Enter your details and the download starts immediately.
No newsletter spam. The form sends me your name, email and the exact resource requested so I can follow up properly.
Where this template applies, and its limits
- England unless stated. The Regulatory Reform (Fire Safety) Order 2005 applies in England and Wales, but the Fire Safety (England) Regulations 2022, the 2022 smoke and carbon monoxide alarm changes and the HMO management regulations described here are England rules. Scotland has the Fire (Scotland) Act 2005 and its own housing law. Northern Ireland has the Fire and Rescue Services (Northern Ireland) Order 2006. Wales has its own housing law. Rules differ, so this pack does not cover those nations, and a Welsh or Scottish landlord should check their own regime.
- A starting point for simple buildings. A small shared house or a small converted building is realistic. It is not suitable on its own for large or complex buildings, tall buildings, buildings with vulnerable residents, or anywhere you cannot see enough of the structure to judge it (fire stopping, cladding, compartmentation).
- Not a PAS 79 or BS 9792 assessment. Assessors use recognised methods. PAS 79-1:2020 is the BSI code of practice for premises other than housing. For housing, including HMOs and blocks of flats, the current code is BS 9792:2025, which replaced the withdrawn PAS 79-2:2020. This template does not reproduce either and completing it does not make an assessment compliant with them.
- Not legal advice. It records what you find. Whether your building needs a licence, or what your council expects, is for your local housing authority.
The rules that matter to an HMO landlord, in plain English
- The responsible person (Fire Safety Order 2005). For premises that are not a workplace, the responsible person is the person who has control of the premises as occupier or otherwise, if they control them in connection with a trade, business or other undertaking, or otherwise the owner. Article 9 requires a suitable and sufficient assessment of the risks, kept up to date, with the findings recorded. The Home Office guide for sleeping accommodation covers the common areas of HMOs. Inside a tenant's own room your duties come mainly from housing law.
- Fire Safety Act 2021. It clarified that, in a building with two or more sets of domestic premises, the Order applies to the building's structure, external walls (including cladding, windows and balconies), common parts and the entrance doors between each flat and the common parts, and responsible persons must consider those parts in their assessments.
- Fire Safety (England) Regulations 2022 (in force 23 January 2023). In a building with two or more sets of domestic premises and common parts that residents would need to use to escape, the responsible person must display fire safety instructions (the evacuation strategy, how to report a fire and what to do once there is a fire), and give a copy to each new resident as soon as reasonably practicable and to all residents at least every 12 months. On the same timetable they must tell residents that fire doors should be kept shut, that self-closers must not be tampered with, and that faults should be reported straight away. In buildings above 11 metres (measured to the top storey, typically five storeys or more), communal fire doors must be checked at least every 3 months, and the responsible person must use best endeavours to check flat entrance doors at least every 12 months and keep a record of attempts to get in. High-rise buildings (at least 18 metres or seven storeys) have further duties. The Home Office describes these buildings as mainly blocks of flats, including converted houses, and does not say how a shared house is treated. Whether a shared house counts as one private dwelling or several decides whether these rules apply, and also how far the Fire Safety Order covers its shared areas. If you are unsure, ask your local fire and rescue service, which enforces these rules.
- Housing Act 2004 and the HHSRS. Fire and explosions is one of the hazards that councils assess under the Housing Health and Safety Rating System. For a serious (Category 1) hazard a council has a duty to take enforcement action, and for a Category 2 hazard it has a power to. A large HMO (at least five tenants forming more than one household and sharing a toilet, bathroom or kitchen) needs a licence from the council, a council can also require licences for smaller HMOs in an area it designates for additional licensing, and councils can attach licence conditions about management, use, and the facilities and equipment the house must have.
- Management of HMOs (England) Regulations 2006, regulation 4. These regulations apply to HMOs in England other than converted blocks of flats covered by section 257 of the Housing Act 2004. The manager must keep all means of escape from fire free from obstruction and in good order and repair, and keep fire-fighting equipment and fire alarms in good working order. Notices showing the escape routes must be displayed where they can be clearly seen, except in an HMO with four or fewer occupiers. The manager must also take reasonable measures to protect occupiers from injury, having regard to the design, structure and number of occupiers.
- Smoke and carbon monoxide alarms (England, amended 1 October 2022). At least one smoke alarm on each storey with a room used as living accommodation (a bathroom or toilet counts), and a carbon monoxide alarm in each room used as living accommodation with a fixed combustion appliance (gas cookers excluded). Alarms must be checked as working on the day a new tenancy begins, and when a tenant reports a fault and the alarm is found not to be working, it must be repaired or replaced as soon as reasonably practicable. Councils can fine up to £5,000 where a landlord fails to comply with a remedial notice. HMOs that must be licensed, and houses that need a selective licence, fall outside those regulations. Instead the Housing Act 2004 requires every such licence to include conditions to fit a smoke alarm on each storey with living accommodation and a carbon monoxide alarm where there is a fixed combustion appliance, and to keep them working.
The LACORS "Housing: Fire Safety" guidance
The LACORS guide Housing: Fire Safety, guidance on fire safety provisions for certain types of existing housing, was published in July 2008 by the Local Authorities Coordinators of Regulatory Services. It covers existing housing, including single-family dwellings, shared houses, bedsits and flats, and is not aimed at new housing built to modern building regulations. It is not one of the Home Office guides issued under article 50 of the Fire Safety Order. GOV.UK lists it as a related publication and as complementary, non-statutory advice that may go beyond what the Order requires, and says it is relevant to landlords, managing agents, local councils and fire and rescue authorities. The Home Office guide for sleeping accommodation, issued under article 50, is the official guide for HMO common areas. Your council may refer to the LACORS guide when it judges fire safety in housing, so ask which standard it applies before you commit to expensive works.
When you can DIY, and when you need an assessor
- DIY is realistic when: the building is small and simple, you can see how it is built, there are no vulnerable residents, and you are prepared to read the official guidance and follow it.
- Bring in a competent fire risk assessor when: the building is large, tall, converted, or has more than a few storeys; you cannot judge fire stopping, compartmentation or cladding; residents need help to escape; there has been a fire or a council notice; your licence or insurer asks for a professional assessment; or you are not sure. Look for third-party registration of the assessor or their company.
- Either way it stays your duty. Hiring an assessor does not move the responsibility off the responsible person.
What is in the pack
- HMO and landlord fire risk assessment (Word): ten sections: property and responsible person, people at risk, hazards (including e-bike batteries and shared kitchens), means of escape, fire doors and compartmentation, detection and alarms, management and resident information, risk rating, action plan and sign-off.
- Resident fire safety instructions and alarm test record (Word): an editable notice for the common parts and new tenants, and a log for the first-day alarm test and routine checks.
- Fire action log (Excel): an action log with Priority and Status dropdowns, an Overdue flag that appears when a target date passes, automatic counts of open, overdue and urgent actions, plus a check log for alarm and fire door tests. Portable formulas that work in Excel and Google Sheets.
For other premises see the general fire risk assessment template, and the master risk assessment template hub for the general workplace assessment every employer needs. Guidance references last checked: 6 November 2026.
Do I need a fire risk assessment for my HMO?
If you let an HMO as a business, you will usually be the "responsible person" for the common parts under the Regulatory Reform (Fire Safety) Order 2005, which applies in England and Wales, and so need a suitable and sufficient fire risk assessment, kept up to date. The Home Office guide for sleeping accommodation covers the common areas of HMOs. If you are not sure whether the Order applies to your arrangement, ask your fire and rescue service or a competent assessor.
What should a landlord fire risk assessment cover?
The people at risk, the ignition and fuel hazards, the escape routes, fire doors, detection and alarms, fire-fighting equipment, how the building is managed and what you tell residents. Section 9 turns the findings into a dated action plan. The Word template in this pack follows that order.
Can I do a fire risk assessment for an HMO myself?
For a small, simple shared house you may be able to, if you are competent and use the official Home Office guidance. For anything large, converted, with several storeys, vulnerable residents, a poor fire history, or where you are unsure what you are looking at, use a competent fire risk assessor. This template does not make an assessment compliant with PAS 79 or BS 9792.
What smoke and carbon monoxide alarms must a landlord fit in England?
GOV.UK says landlords must have at least one smoke alarm on each storey with a room used as living accommodation, and a carbon monoxide alarm in each room used as living accommodation that has a fixed combustion appliance (gas cookers excluded). Since 1 October 2022 landlords must repair or replace an alarm that a tenant reports and that is found to be faulty, and alarms must be checked as working on the day a new tenancy begins. HMOs that must be licensed are covered by alarm conditions in their licence instead.
Is there a fire risk assessment template for flats?
This template is written for HMOs and shared houses, but the same sections work for the common parts of a small block of flats. For a block of flats use the Home Office guide Making your small block of flats safe from fire first, and bring in an assessor for anything larger or more complex.
Is this PAS 79 compliant?
No, and it does not claim to be. PAS 79-1:2020 is the BSI code of practice for premises other than housing. For housing, including HMOs and blocks of flats, the current BSI code of practice is BS 9792:2025, which replaced the withdrawn PAS 79-2:2020. Assessors work to those methods. This template is a plain record to help you organise a simple assessment.
Related tools
Sources
The legal statements on this page were checked against the primary sources below. Each link was opened and checked on 6 November 2026.
- legislation.gov.uk: Regulatory Reform (Fire Safety) Order 2005, article 3: who the responsible person is (England and Wales).
- legislation.gov.uk: Fire Safety Order 2005, article 9: the risk assessment duty, review and recording.
- legislation.gov.uk: Fire Safety Order 2005, article 2 and article 6: the meaning of domestic premises, and the parts of buildings with two or more sets of domestic premises that the Order covers (added by the Fire Safety Act 2021).
- GOV.UK: Fire safety risk assessment, sleeping accommodation: the Home Office guide covering the common areas of HMOs, with the LACORS guide listed as a related publication.
- GOV.UK: Fire safety guidance for those with legal duties: the Home Office guides by premises type, including small blocks of flats and purpose-built blocks.
- GOV.UK: Fire Safety Act 2021: structure, external walls and flat entrance doors.
- legislation.gov.uk: Fire Safety (England) Regulations 2022: regulations 1 (23 January 2023, England only), 3, 9 and 10.
- GOV.UK: Check your fire safety responsibilities under the Fire Safety (England) Regulations 2022: which buildings the regulations apply to, how height is measured, and who enforces them.
- GOV.UK: Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022, guidance for landlords and tenants: alarm duties, the repair duty, HMOs and penalties.
- legislation.gov.uk: Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 2 and regulation 4: HMOs and houses that need a licence are outside the regulations; the landlord's alarm duties.
- legislation.gov.uk: Housing Act 2004, Schedule 4, paragraph 1: the smoke and carbon monoxide alarm conditions every licence must include.
- GOV.UK: Landlord and agent guide to the HHSRS: Category 1 and 2 hazards and council enforcement.
- legislation.gov.uk: Housing Act 2004, section 55 and section 67: HMO licensing, additional licensing and licence conditions.
- GOV.UK: Houses in multiple occupation: HMO and large HMO definitions, and the licence for large HMOs.
- legislation.gov.uk: Management of Houses in Multiple Occupation (England) Regulations 2006, regulation 4: the manager's fire safety duties (and regulation 1 for which HMOs they apply to).
- LACORS clarification note on Housing: Fire Safety (hosted by Guildford Borough Council): the full title of the 2008 guide and its July 2008 publication date.
- BSI: BS 9792:2025: the current code of practice for housing, which replaced the withdrawn PAS 79-2:2020.
- BSI: PAS 79-1:2020: the code of practice for premises other than housing.
How ours differs from the official material: the Home Office guides explain what to look for. This pack is an editable record to write your findings and actions into, a notice for residents, and a spreadsheet to track the fixes. Use the Home Office guide for your type of building alongside it.
Digital Adaption also does paid data migration and reporting work for UK businesses; contact us if that would help.